Diagnostic
Tanı, Tedavi ve Araştırma amaçlı kullanılan Transkraniyel Manyetik Stimülatör Serisi
USB Bağlantı | |
ISO Belgelendirme |
USB Bağlantı | |
ISO Belgelendirme |
Coils
The stimulator can be equipped with a wide range of cooled and non-cooled stimulating coils of different shape and size: ring, figure-of-eight, angulated figure-of-eight. For research purposes a device can be supplied with placebo coils. Above standard coils Neurosoft Company develops coils according to customer requests: animal, air-cooled and specially shaped ones.
Modular ConstructionNew version of magnetic stimulator consists of several separate units, thus you can select the configuration required for you. We offer you several ready-made configuration variants that can be most conveniently applied for the practical use.
Neuro-EMG-MS is a Special Device to Record Motor Evoked PotentialsThis device is EMG amplifier. If you connect it to computer, you can record the motor evoked potentials obtained at TMS stimulation of motor areas of cerebral cortex and peripheral nervous system. When you record the motor evoked potentials, you can define the so called motor threshold (MT). This is a very important parameter. As far the stimulation amplitude at performing of treatment procedures is often set relative to obtained MT. Neuro-MS.NET SoftwareThe delivery set includes the special software for magnetic stimulator control with the use of computer. This software allows keeping the patient database, detecting motor response threshold, controlling the stimulation courses and sessions. A user can perform the stimulation according to already specified stimulation programs and also create own ones or edit the available stimulation programs. New Coil HolderNow Neuro-MS/D delivery set (research variant) includes FISSO holder to fix the magnetic stimulator coil. It very convenient as it can be fixed in any position by rotating one screw. You can order this coil holder for other delivery set variants. Specialized ComputerThe device can be both equipped with common computer and specialized one with touchscreen interface. Neuro-MS.NET is specially adapted finger-controlled software. It allows controlling the magnetic stimulator operation quickly and conveniently. Operation with Any Neurophysiological EquipmentNeuro-MS/D magnetic stimulator can operate jointly with neurophysiological equipment manufactured by Neurosoft Ltd. and also digital EMG systems of third-party manufacturers. To connect to EMG systems of third-party manufacturers, the trigger socket is provided. The special trigger unit can also be applied to adjust the trigger pulse parameters. |
|
|
The diagnostic variant of magnetic stimulator is intended first of all for joint operation with neurophysiological (EMG) equipment to study the state of cerebral, spinal and peripheral pathways.
The maximum diagnostic capabilities can be shown if the device is used together with neurophysiological digital system manufactured by Neurosoft Ltd. However, the magnetic stimulator can operate with devices of other manufacturers.
Neuro-MS/D (Therapeutic) Applications:
Neurology:
Ophthalmology:
Psychiatry:
The delivery set of therapeutic variant includes Neuro-MS.NET software allowing to program any stimulation algorithms. It also provides theta-burst mode with up to 100 Hz stimulation frequency.
In case the therapeutic variant is equipped with neurophysiological equipment, it will receive all capabilities of diagnostic variant.
The magnetic stimulator can be successfully used to make rehabilitation prognosis for stroke patients. At that the following parameters are studied:
All parameters are recorded separately from right and left sides.
** screenshots of Neuro-MEP.NET software which is supplied optionally
Study of root conduction time | Tripple stimulation test | Study of central motor conduction time | Motor response variability |
If you want to know more about the magnetic stimulation, we recommend reading the following literature:
Neuro-MS/D magnetic stimulator has 4 delivery set variants:
Variant 1 — «Diagnostic»
Variant 2 — «Therapeutic»
Variant 3 — «Advanced Therapeutic»
Variant 4 — «Research»
List of Components | Variant 1 | Variant 2 | Variant 3 | Variant 4 |
---|---|---|---|---|
“Neuro-MS/D” main unit | 1 | 1 | 1 | 1 |
“Neuro-MS/D” extra power supply unit | — | — | 1 | 1 |
“Neuro-MS/D” expansion unit | — | — | — | 1 |
Coil support | 1 | — | — | — |
“Neuro-MS/D” cooling unit | — | 1 | 1 | 1 |
Trolley with custors for magnetic stimulator | — | 1 | 1 | 1 |
FISSO coil holder | — | — | 1 | 1 |
Manfrotto coil holder | — | 1 | 1 | — |
Big ring coil RC-02-150 | 1 | — | — | — |
Small ring coil RC-02-100 | 1 | — | — | — |
Figure-of-eight coil FEC-02-100 | 1 | — | — | — |
Cooled angulated figure-of-eight coil AFEC-02-100-C | — | 1 | 1 | 1 |
HV cable for Neuro-MS/D extra power supply unit | — | — | 1 | 1 |
Hydraulic adapter | — | 2 | 2 | 2 |
Control cable for Neuro-MS/D cooling unit | — | 1 | 1 | — |
Control cable forNeuro-MS/D cooling and expansion units | — | — | — | 1 |
Equipotential cable | — | 1 | 2 | 3 |
End cap | 1 | 1 | 1 | 1 |
Neuro-MEP Micro (version 2009) | — | — | — | 1 |
Neuro-MS.NET software | — | 1 | 1 | 1 |
Technical manual | 1 | 1 | 1 | 1 |
User manual | 1 | 1 | 1 | 1 |
AVM Sağlık Sistemleri ürün ve hizmetleri konusunda ilgileniyor ve yeniliklerden haberdar olmak istiyorsanız; bizi takip edin...
|
AVM Sağlık Hizmetleri Ltd. Şti.
Küçükbakkalköy Mh. Gül Ağacı Sk.
No:13 34750 Ataşehir - İstanbul
Tel: +90 (216) 368 18 00
Faks: +90 (216) 368 19 00
E-posta: bilgi@avmsaglik.com.tr