Neuro-Audio-Screen — system for hearing screening and diagnostic tests

  • Auditory brainstem response / brainstem evoked response audiometry (ABR / BERA) for in-depth screening
  • The device can be referred to diagnostic class because of the possibility to perform the techniques in expert mode
  • The exams can be exported instantly to patient database of medical institution via Bluetooth
  • The test results can be printed on a portable or standard laser printer

Why is it Important?

The hearing impairment is diagnosed in three of every thousand babies born, that is twice more than frequency of cleft lip (palate), twice more than frequency of Down’s syndrome and ten times more than frequency of phenylketonuria.

The problem of diagnostics and treatment of hearing loss and deafness in this special category of patients is actual both in medical and social relations. Often the visual examination and other traditional diagnostic techniques of hearing impairment detection do not reveal the problem until 1 to 3 years of age — which is well beyond the critical period (6 months) for healthy speech and language development.

However, if a hearing impairment is identified and treated in its early stages, studies have shown that the child’s speech and language skills will be comparable to his or her normal-hearing peers. For these reasons, hearing screening at birth and routinely throughout childhood is extremely important. Timely and correct diagnosis provides an opportunity to start the hearing rehabilitation and child integration to speech environment as soon as possible.

What Should be Done?

Earlier to solve the specified problem, the hearing screening of newborns and babies was applied. It was based on the consideration of risk factors with the further examination of babies, included in the risk group, in specialized establishments. However, at such approach 50% of children drop out of sight.

The only possible solution of the problem concerning early detection and rehabilitation of children suffering from hearing loss and deafness is introduction of hearing screening with the use of objective technologies in maternity hospitals and maternity departments of patient care institutions.

At present time, the fundamentally new so called objective techniques of hearing study are developed and applied in clinical practice, they are computer audiometry by auditory brainstem response (ABR) and recording of otoacoustic emission (OAE). It allows performing hearing study in any age, even in newborns.

Device Usability

The whole front panel of the device is 4.3″ touch screen. The menu with the list of available tests will be displayed on the screen after device switching on. You should insert OAE probe into a patient’s ear properly and start the test by touching the screen two times. The program will inform you if the OAE probe is inserted incorrectly. The test will be performed in automatic mode if everything is correct. After the test the program will give “PASS” or “REFER” result. It is quite simple. Detailed video guide supplied with Neuro-Audio-Screen will help you to master the program operation.

The system is real easy to use even for untrained medical personnel including nursing staff.

Wireless Bluetooth Interface

Wireless Bluetooth Interface provides the opportunity to print exam results on wireless printer and export data saved in the device memory to the external computer with installed Neuro-Audio-Screen Manager. The program is supplied free with the device.

Neuro-Audio-Screen Manager Software

Neuro-Audio-Screen Manager works on Windows-based computer. Using this program you can prepare a list of patients you plan to examine, export exams to the computer database, print results or export to Neuro-Audio.NET software.

Compatibility of Data Format with Neuro-Audio Diagnostic OAE and EP System

Compatibility of data format with Neuro-Audio (version 2010) diagnostic OAE and EP System provides continuity of diagnostic information obtained during hearing screening and during specialized diagnostic research.

Customizable Settings

You can change test settings using the configuration menu. For example, you can use different modes of OAE test: "Screening", "Noisy (screening)", etc. It helps to customize settings quickly in order to perform any hearing exam starting from screening in a noisy room and up to expert study in a specialized hospital.

 Neuro-Audio-Screen Features

Neuro-Audio-Screen Features

 ABR / BERA

When you use only OAE technique for screening, patients with normal cochlea function but with possible retrocochlear impairments (for example, with auditory neuropathy) drop out of sight. The ABR technique does not have such drawback.

The essence of this technique is the acquisition of the electrical potentials evoking in different structures of auditory system in response to auditory signal which defines its objectivity.

Auditory brainstem response (ABR) or brainstem evoked response audiometry (BERA) is widely used in audiology.

The advantages of this test:

  • ABR can be recorded in newborn from first hours of life including premature infants and newborns suffering from central nervous system diseases.
  • ABR acquisition is noninvasive (safe and harmless).
  • ABR acquisition provides objective information concerning the state of auditory pathways.
  • ABR characteristics are stable and do not depend on a patient’s state (whether she/he is awake or asleep, this sleep is natural or drug-induced).

Besides, ABR screening has the following advantages:

  • The stimulation frequency is increased up to 93 Hz, it allows making 8000 averagings per less than 2 minutes.
  • The test has several automatically calculated "Pass" criteria. As soon as these criteria are checked, the test is stopped automatically and "PASS" or "REFER" result is displayed on the screen.
  • To record ABR, the same OAE probe as for OAE acquisition is used.

During two-stage hearing screening, in case an infant did not pass OAE test, a doctor should make ABR test to specify the diagnosis.

 

neuroaudioscreen 03kDevice Usability

The whole front panel of the device is 4.3″ touch screen. The menu with the list of available tests will be displayed on the screen after device switching on. You should insert OAE probe into a patient’s ear properly and start the test by touching the screen two times. The program will inform you if the OAE probe is inserted incorrectly. The test will be performed in automatic mode if everything is correct. After the test the program will give “PASS” or “REFER” result. It is quite simple. Detailed video guide supplied with Neuro-Audio-Screen will help you to master the program operation.

The system is real easy to use even for untrained medical personnel including nursing staff.

Wireless Bluetooth Interface

Wireless Bluetooth Interface provides the opportunity to print exam results on wireless printer and export data saved in the device memory to the external computer with installed Neuro-Audio-Screen Manager. The program is supplied free with the device.

Neuro-Audio-Screen Manager Software

Neuro-Audio-Screen Manager works on Windows-based computer. Using this program you can prepare a list of patients you plan to examine, export exams to the computer database, print results or export to Neuro-Audio.NET software.

Compatibility of Data Format with Neuro-Audio Diagnostic OAE and EP System

Compatibility of data format with Neuro-Audio (version 2010)Diagnostic OAE and EP System provides continuity of diagnostic information obtained during hearing screening and during specialized diagnostic research.

Customizable Settings

You can change test settings using the configuration menu. For example, you can use different modes of OAE test: "Screening", "Noisy (screening)", etc. It helps to customize settings quickly in order to perform any hearing exam starting from screening in a noisy room and up to expert study in a specialized hospital.

Two delivery set variants are available: Neuro-Audio-Screen and Neuro-Audio-Screen/OAE
All devices are calibrated at Neurosoft facilities.

 Available Techniques
ABRTEOAEDPOAE
 
Neuro-Audio-Screen (FULL) 
 
+ + +
Neuro-Audio-Screen (ABR/BERA) + - -
 
Neuro-Audio-Screen/OAE 
 
+ +

 

Neuro-Audio-Screen Delivery Set

Neuro-Audio-Screen Extra Delivery Set

avmlogo

AVM Sağlık Sistemleri ürün ve hizmetleri konusunda ilgileniyor ve yeniliklerden haberdar olmak istiyorsanız; bizi takip edin...

encoksatan logo

orjinal-urun

İletişim

AVM Sağlık Hizmetleri Ltd. Şti.

Küçükbakkalköy Mh. Gül Ağacı Sk.
No:13 34750 Ataşehir - İstanbul

Tel: +90 (216) 368 18 00
Faks: +90 (216) 368 19 00

E-posta: bilgi@avmsaglik.com.tr